misha_series_oxygen

MISHA Series Medical Oxygen Generation System

Misha Series Oxygen Generator Systems offer oxygen from generators that can be filled into cylinders by using booster pumps. The compressor can fill cylinders at 2200. Bulk and ward cylinders can be filled onsite.

Number of cylinders which can be filled in 24 hours depends on the size of the booster compressor.

Robust and reliable, have been working for more than 50 years.

All size oxygen generator plants available from small nursing home to big hospitals.

Model

MISHA15

15Nm3/hr

93% + 3%

250 LPM

MISHA23

23Nm3/hr

93% + 3%

380 LPM

MISHA30

30Nm3/hr

93% + 3%

500 LPM

MISHA45

45Nm3/hr

93% + 3%

750LPM

MISHA60

60Nm3/hr

93% + 3%

1000LPM

150bar Booster

For 40L Cylinder

2.5 Cylinder/h

50 Cylinders/

20 hours

3.83 Cylinder/h

76.7 Cylinders/

20 hours

5 Cylinder/h

100 Cylinders/

20 hours

7.5 Cylinder/h

150 Cylinders/

20 hours

10 Cylinder/h

200 Cylinders/

20 hours

Part 1: Air Compressor

Power: 30KW

Flow Rate: 5.0Nm3/min

Pressure: 0.8Mpa

Voltage: 380V 50Hz

Air Receiver: 1.5m3

Power: 37KW

Flow Rate: 6.2Nm3/min

Pressure: 0.8Mpa

Voltage: 380V 50Hz

Air Receiver: 1.0m3

Power: 45KW

Flow Rate: 9.0Nm3/min

Pressure: 0.8Mpa

Voltage: 380V 50Hz

Air Receiver: 1.5m3

Power: 55KW

Flow Rate: 9.0Nm3/min

Pressure: 0.8Mpa

Voltage: 380V 50Hz

Air Receiver: 1.5m3

Power: 90KW

Flow Rate: 15.7Nm3/min

Pressure: 0.8Mpa

Voltage: 380V 50Hz

Air Receiver: 2.0m3

Part 2: Refrigerated Air Dryer

Flow Rate: 6.8Nm3/min

Max pressure: 1.0Mpa

Dew Point:  2°C - 10°C

Voltage: 380V 50Hz

Voltage: 3KW

Flow Rate: 6.8Nm3/min

Max pressure: 1.0Mpa

Dew Point:  2°C - 10°C

Voltage: 380V 50Hz

Voltage: 3KW

Flow Rate: 10.5Nm3/min

Max pressure: 1.0Mpa

Dew Point:  2°C - 10°C

Voltage: 380V 50Hz

Voltage: 3KW

Flow Rate: 10.5Nm3/min

Max pressure: 1.0Mpa

Dew Point:  2°C - 10°C

Voltage: 380V 50Hz

Voltage: 3KW

Flow Rate: 17.5Nm3/min

Max pressure: 1.0Mpa

Dew Point:  2°C - 10°C

Voltage: 380V 50Hz

Voltage: 4KW

Part : Desiccant Air Dryer

Flow Rate: 6.8Nm3/min

Max Pressure: 1.0Mpa

Dew Point: -20 ~ 60°C

Voltage: 220V 50Hz

Flow Rate: 6.8Nm3/min

Max Pressure: 1.0Mpa

Dew Point: -20 ~ 60°C

Voltage: 220V 50Hz

Flow Rate: 10.5Nm3/min

Max Pressure: 1.0Mpa

Dew Point: -20 ~ 60°C

Voltage: 220V 50Hz

Flow Rate: 10.5Nm3/min

Max Pressure: 1.0Mpa

Dew Point: -20 ~ 60°C

Voltage: 220V 50Hz

Flow Rate: 17.5Nm3/min

Max Pressure: 1.0Mpa

Dew Point: -20 ~ 60°C

Voltage: 220V 50Hz

Part 4: PSA Oxygen Generator

Flow Rate: 15Nm3/hr

Purity: 93% + 3%

Pressure: 0.4Mpa

Dew Point: < -40°C

Voltage: 220V 50Hz

Power: 0.5KW

Flow Rate: 23Nm3/hr

Purity: 93% + 3%

Pressure: 0.4Mpa

Dew Point: < -40°C

Voltage: 220V 50Hz

Power: 0.5KW

Flow Rate: 30Nm3/hr

Purity: 93% + 3%

Pressure: 0.4Mpa

Dew Point: < -40°C

Voltage: 220V 50Hz

Power: 0.5KW

Flow Rate: 30Nm3/hr

Purity: 93% + 3%

Pressure: 0.4Mpa

Dew Point: < -40°C

Voltage: 220V 50Hz

Power: 0.5KW

Flow Rate: 60Nm3/hr

Purity: 93% + 3%

Pressure: 0.4Mpa

Dew Point: < -40°C

Voltage: 220V 50Hz

Power: 0.5KW

Part 5: O2 Booster

Flow Rate: 15Nm3/hr

Inlet Pressure: 0.4Mpa

Outlet Pressure: 20.0Mpa

Voltage:380V 50Hz

Power: 18.5KW

Flow Rate: 23Nm3/hr

Inlet Pressure: 0.4Mpa

Outlet Pressure: 20.0Mpa

Voltage:380V 50Hz

Power: 18.5KW

Flow Rate: 30Nm3/hr

Inlet Pressure: 0.4Mpa

Outlet Pressure: 20.0Mpa

Voltage:380V 50Hz

Power: 18.5KW

Flow Rate: 45Nm3/hr

Inlet Pressure: 0.4Mpa

Outlet Pressure: 20.0Mpa

Voltage:380V 50Hz

Power: 18.5KW

Flow Rate: 60Nm3/hr

Inlet Pressure: 0.4Mpa

Outlet Pressure: 20.0Mpa

Voltage:380V 50Hz

Power: 18.5KW

MISHA Series Medical Oxygen Generation